Used, in good optical condition.
Magnification: 2.0x
Working Distance: 31 mm.
Compatibility: It is compatible with the Stemi 305 508 DV4 stereo microscope .
M50 thread.
Used, in good optical condition.
This objective lens is suitable for both transmitted and reflected light.
Free working distance: 4.0mm
This is a series of objectives for the examination of materials. They differ from Epiplan objectives by their higher NA and, accordingly, higher resolving power and like all EC objectives they are optimized for highest contrast. Unlike the Epiplan series, the EC Epiplan-Neofluar series includes 1.25x and 2.5x objectives. These low-power objectives provide maximum object field diameters up to 20 mm. EC Epiplan-Neofluar objectives are also suitable for transmitted-light work. Because of spherical aberration, specimens with cover glass should not be observed with an objective magnification above 20x. There are no restrictions for uncovered specimens. Due to their strict telecentricity on the object side, these objectives are ideal for measuring purposes.They differ from Epiplan objectives by their higher NA and, accordingly, higher resolving power and of course like all EC objectives for highest contrast. Unlike the Epiplan series, the EC Epiplan-Neofluar series includes 1.25x and 2.5x objectives. These low-power objectives provide maximum object field diameters of 20 mm.EC Epiplan-Neofluar objectives are also suitable for transmitted-light work. Because of spherical aberration, specimens with cover glass should not be observed with objective powers above 20x.There are no restrictions for uncovered specimens.
Used, in good optical condition.
Free Working Distance(mm) : 9.0
This objective lens is suitable for both transmitted and reflected light.
EC Epiplan-Neofluar
This is a series of objectives for the examination of materials. They differ from Epiplan objectives by their higher NA and, accordingly, higher resolving power and like all EC objectives they are optimized for highest contrast. Unlike the Epiplan series, the EC Epiplan-Neofluar series includes 1.25x and 2.5x objectives. These low-power objectives provide maximum object field diameters up to 20 mm. EC Epiplan-Neofluar objectives are also suitable for transmitted-light work. Because of spherical aberration, specimens with cover glass should not be observed with an objective magnification above 20x. There are no restrictions for uncovered specimens. Due to their strict telecentricity on the object side, these objectives are ideal for measuring purposes.They differ from Epiplan objectives by their higher NA and, accordingly, higher resolving power and of course like all EC objectives for highest contrast. Unlike the Epiplan series, the EC Epiplan-Neofluar series includes 1.25x and 2.5x objectives. These low-power objectives provide maximum object field diameters of 20 mm.EC Epiplan-Neofluar objectives are also suitable for transmitted-light work. Because of spherical aberration, specimens with cover glass should not be observed with objective powers above 20x.There are no restrictions for uncovered specimens.
Used, in good optical condition.
This objective lens is suitable for both transmitted and reflected light.
Free working distance:15.1mm
EC Epiplan-Neofluar
This is a series of objectives for the examination of materials. They differ from Epiplan objectives by their higher NA and, accordingly, higher resolving power and like all EC objectives they are optimized for highest contrast. Unlike the Epiplan series, the EC Epiplan-Neofluar series includes 1.25x and 2.5x objectives. These low-power objectives provide maximum object field diameters up to 20 mm. EC Epiplan-Neofluar objectives are also suitable for transmitted-light work. Because of spherical aberration, specimens with cover glass should not be observed with an objective magnification above 20x. There are no restrictions for uncovered specimens. Due to their strict telecentricity on the object side, these objectives are ideal for measuring purposes.They differ from Epiplan objectives by their higher NA and, accordingly, higher resolving power and of course like all EC objectives for highest contrast. Unlike the Epiplan series, the EC Epiplan-Neofluar series includes 1.25x and 2.5x objectives. These low-power objectives provide maximum object field diameters of 20 mm.EC Epiplan-Neofluar objectives are also suitable for transmitted-light work. Because of spherical aberration, specimens with cover glass should not be observed with objective powers above 20x.There are no restrictions for uncovered specimens.
Used, in good optical condition.
This objective lens is suitable for both transmitted and reflected light.
Magnification : 5x
Numerical Aperture : 0.13
Free Working Distance : 14.5[mm]
Coverglass Thickness : 0[mm]
Thread Type : M27
Immersion : Without Immersion
Field of View [mm] : 25
Optical System : Infinity Color Corrected System (ICS)
Color Correction : semi-apochromatic
Unused, in mint condition from storage.
Price:650$
Part Number: 424940-9060-000
Reflector turret 4x man., changeable, for P&C modules
This article is compatible with the microscope(s) listed below. Attention: The list also includes microscopes that are no longer available in the current program.
Axio Scope.A1
Axio Scope.A1 Vario
Axio Examiner.A1
Axio Scope.A1 Pol
Used,in good optical condition.
Zeiss Ultrafluar 10X ultraviolet light and visible light objective lens
This objective requires the use of quartz cover slips.
The objective is sensitive to temperature fluctuations.
Transmittance curve: